Donaldson Hy-Pro's hand-truck mobile filter cart for hydraulic oil, lube oil, and diesel up to ISO VG100. Self-contained pump-motor combination, never-flat foam tires, and a 35-foot retractable cord reel let one cart serve every reservoir on the floor. Flow rates from 0.5 to 22 gpm.
FC Filter Cart
Product Overview
When you're past the "small gearbox" stage where a CFU fits but you don't yet need the heavy-element FCL for high-viscosity work, the FC is the cart that does the bulk of plant filtration work. Hand-truck-style mobility, never-flat tires, and a self-contained pump-motor combination move from reservoir to reservoir without trailing extension cords or scaring up another forklift.
Two MF110 cartridge filter assemblies in series for staged particulate and water removal in a single pass
DFE-rated G8 Dualglass media with β3[C] ≥ 4000 capture efficiency
Cast iron positive-displacement gear pump with internal relief valve
35' (11 m) retractable electric cord reel keeps the work area clean and snag-free
Never-flat foam-filled pneumatic tires roll over thresholds, gratings, and rough shop floors
Standard upstream and downstream sample ports for before/after fluid analysis
Ergonomic hand-truck handle and removable spill-retention pan included standard
Spin-on element option converts the FC to up to four S75 elements for service-light operations
Optional PM-1 particle monitor delivers real-time ISO cleanliness data, no bottle samples needed
Color-coordination available to match facility safety standards
10 gpm. Most-popular size. Mid-volume hydraulic and lube reservoirs, fluid transfer between drums and tanks.
FC20
22 gpm. Larger reservoirs, faster transfer, and bulk fluid handling. Step up to FCL for higher viscosities.
Specifications
Height
45" (114 cm)
Width × Depth
20" × 23" (50 × 58 cm)
Weight
125 lb (57 kg)
Flow Rate Range
0.5–22 gpm
Electric Motor
0.5–3 hp TEFC, 1450–1750 RPM
Cord Reel
35' (11 m) Retractable
ΔP Indicator Trigger
22 psi (1.5 bar)
Filter Bypass
25 psid (1.7 bard)
Pump Bypass
150 psi (10 bar) Full Bypass
Viscosity Range
2–5,000 cSt
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Connections (Vary by Flow Rate)
1" to 1.5" Male JIC, 37° Flare
Media Options
M — G8 DualglassA — Dualglass + Water RemovalW — Stainless Wire Mesh
Available in 1, 3, 6, 12, 16, and 25 micron grades. M and A media deliver β3[C] ≥ 4000 efficiency on MF110 elements. Specify P9 (phosphate ester) or S9 (Skydrol) compatibility for synthetic fluids.
Power & Hazardous-Area Options
120–575V ACSingle or Three Phase50Hz / 60HzPneumatic Air MotorExplosion Proof Class 1 Div 1MSP IP65 EnclosureCE Marked
Service & Monitoring Options
PM-1 Particle MonitorFilter Bypass LineInlet Pressure GaugeY-Strainer InletSpin-On Element ConversionCustom Color Coordination
Typical Applications
Hydraulic and lube reservoir conditioning across multiple machines on a plant floor
New-oil filtration during transfer from drums or totes into operating reservoirs
Gearbox pump-outs and oil change service on injection molders, presses, and stamping equipment
Diesel fuel transfer and conditioning for #2 fuels (use FCLCOD if water removal is the priority)
Field service work where one cart serves an entire facility's offline filtration needs
Fleet shops, marine engine rooms, and mobile equipment maintenance
Hazardous-area service using the pneumatic or explosion-proof options
Get Started
Tell us your fluid type, viscosity range, target flow rate, and whether you need explosion-proof or pneumatic. We'll spec the right FC size, media, and power configuration.